Skip to content

LED indication during updates

JP150PCB 1.3PCB 1.4since 26.10.1Jan PřibyslavskýThis page does not apply to the product or PCB revision chosen in the header.

In update mode the status LED and the six-LED level meter show what the bootloader does. The colours are chosen so that they cannot be mistaken for an audio level: the meter shows blue only during an update.

State Status LED Level meter
Waiting for an update it was sent to; returns to the firmware by itself after 5 minutes Amber, slow blink (1 s) Dark
Waiting without a timeout: no valid firmware, three failed starts, or the encoder button held at power-up Amber, fast blink (0.25 s) Dark
Transfer in progress Amber, as before Fills blue, one LED per 18 %
Installed, restarting Green, steady All six blue
Failed Red, blinking Frozen where it stopped
Transfer aborted, cable pulled, idle timeout Back to the waiting pattern Dark

The module does not show the cause of a failure; MuraLink reads it from the module and names it. Blinking pauses for a moment while the bootloader erases or writes flash; the colour stays.

The other indicator patterns of the module are on Indicators and LEDs.